CVE-2026-17429
IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, FW950.00 through FW950.H2, OP940.00 through OP940.a1 (Power9), and OP940.00 - OP940.81 (Power HMC) is affected by a vulnerability in the interface between the BMC/FSP and the host system. An attacker with service account or root access to the BMC/FSP can write arbitrary data to hardware control registers, allowing full control over the host system and all hosted partitions, resulting in a confidentiality, integrity, and availability impact.
弱点类型
IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, FW950.00 through FW950.H2, OP940.00 through OP940.a1 (Power9), and OP940.00 - OP940.81 (Power HMC) is affected by a vulnerability in the interface between the BMC/FSP and the host system. An attacker with service account or root access to the BMC/FSP can write arbitrary data to hardware control registers, allowing full control over the host system and all hosted partitions, resulting in a confidentiality, integrity, and availability impact.
受影响产品
- ibm power_system_s1122_\(9824-22a\)_firmware
- ibm power_system_s1122_\(9824-22a\)
- ibm power_system_s1124_\(9824-42a\)_firmware
- ibm power_system_s1124_\(9824-42a\)
- ibm power_system_s1122s_\(9824-22b\)_firmware
- ibm power_system_s1122s_\(9824-22b\)
- ibm power_system_s1114_\(9824-41b\)_firmware
- ibm power_system_s1114_\(9824-41b\)