Tutte le CVE degli ultimi sei mesi, aggiornate ogni giorno.
Vulnerabilità pubblicate direttamente dal National Vulnerability Database, con gravità, classe CWE e prodotti interessati. Cercale, filtrale e guarda cosa è uscito oggi.
- 462 pubblicate nelle ultime 24 ore
- 2979 negli ultimi 7 giorni
- 58.202 negli ultimi sei mesi
Fonte: NVD (National Vulnerability Database) · Aggiornato il 23 set 2026
Mostrate 9 di 9
In Sooma 2GEN brain stimulator, an attacker within Bluetooth range can make unauthenticated changes to brain stimulation parameters.
Arc is an open, SQL-native time-series database for telemetry. Prior to version 26.06.1, Arc Enterprise's cluster replication receiver at `internal/cluster/replication/receiver.go` validates only the wire-format envelope (length, opcode) of inbound messages. T
Coturn is a free open source implementation of TURN and STUN Server. Prior to 4.15.0, an on-path attacker can append attributes after MESSAGE-INTEGRITY to an authenticated STUN request on plain UDP or TCP, adjust the STUN header length, and recompute the unkey
Improper enforcement of message integrity in PostgreSQL GSSAPI support allows a user to negotiate GSSAPI contrary to pg_hba.conf rules, via initial direct TLS connection. Despite a pg_hba.conf that appears to require GSSAPI, the connection may exchange data ov
CWE-924postgresql postgresqlImproper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability in Mitsubishi Electric MELSEC MX Controller MX-R model, MELSEC MX Controller MX-F model, Master/local module, CC-Link IE TSN interface board, Motion module,
Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability in Erlang/OTP ssl (tls_gen_connection module) allows a network-positioned attacker to inject unauthenticated plaintext that the TLS client application later
DVP80ES3 with Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability.
Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause
An authenticated SSH client that repeatedly opened channels which were rejected by the server caused unbounded memory growth, eventually crashing the server process and affecting all connected users. Rejected channels are now properly removed from the connecti
CWE-924golang crypto
Trova il bug prima di un attaccante.
Accedi con GitHub e avvia il tuo primo audit in meno di un minuto. Il piano gratuito non richiede carta di credito.