Все CVE за последние шесть месяцев, обновляются ежедневно.
Опубликованные уязвимости напрямую из National Vulnerability Database: критичность, класс CWE и затронутые продукты. Ищите, фильтруйте и смотрите, что появилось сегодня.
- За последние 24 часа: 294
- За последние 7 дней: 2 895
- За последние шесть месяцев: 58 248
Источник: NVD (National Vulnerability Database) · Обновлено 23 сент. 2026 г.
Показано 9 из 9
In Sooma 2GEN brain stimulator, an attacker within Bluetooth range can make unauthenticated changes to brain stimulation parameters.
Arc is an open, SQL-native time-series database for telemetry. Prior to version 26.06.1, Arc Enterprise's cluster replication receiver at `internal/cluster/replication/receiver.go` validates only the wire-format envelope (length, opcode) of inbound messages. T
Coturn is a free open source implementation of TURN and STUN Server. Prior to 4.15.0, an on-path attacker can append attributes after MESSAGE-INTEGRITY to an authenticated STUN request on plain UDP or TCP, adjust the STUN header length, and recompute the unkey
Improper enforcement of message integrity in PostgreSQL GSSAPI support allows a user to negotiate GSSAPI contrary to pg_hba.conf rules, via initial direct TLS connection. Despite a pg_hba.conf that appears to require GSSAPI, the connection may exchange data ov
CWE-924postgresql postgresqlImproper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability in Mitsubishi Electric MELSEC MX Controller MX-R model, MELSEC MX Controller MX-F model, Master/local module, CC-Link IE TSN interface board, Motion module,
Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability in Erlang/OTP ssl (tls_gen_connection module) allows a network-positioned attacker to inject unauthenticated plaintext that the TLS client application later
DVP80ES3 with Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability.
Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause
An authenticated SSH client that repeatedly opened channels which were rejected by the server caused unbounded memory growth, eventually crashing the server process and affecting all connected users. Rejected channels are now properly removed from the connecti
CWE-924golang crypto
Найдите уязвимость раньше атакующего.
Войдите через GitHub и запустите первый аудит меньше чем за минуту. Для бесплатного тарифа банковская карта не нужна.